Reporting Standards: CONSORT-AI, SPIRIT-AI, TRIPOD+AI, and STARD

The major reporting guidelines for AI clinical studies and diagnostic accuracy studies. What each standard requires, when each applies, and how to use them as a checklist during study design — not just at manuscript submission.


If you have published a clinical trial you already know CONSORT, the checklist that makes you say how patients were randomized and what happened to the ones who dropped out. Reporting guidelines like it exist because readers kept finding that papers left out the details needed to judge them.

AI studies have the same problem with extra things to leave out: which version of the model was used, what data it was trained on, how the output reached the clinician. So over the last few years most of the major guidelines have grown an AI version. There are now enough of them that picking the right one is a small research project. This article is the map.

What a reporting guideline is and isn't

A reporting guideline is a list of things a paper has to tell the reader. It says nothing about whether the study was any good. You can run a poor study and report it perfectly, and the guideline will be satisfied. (Readers will not be, which is rather the point: complete reporting lets them see the weaknesses.)

That distinction separates reporting guidelines from risk of bias tools such as QUADAS-2 for diagnostic accuracy studies and PROBAST for prediction models. Those are used by reviewers and by authors of systematic reviews to judge how trustworthy a study is. We come back to them below.

Most guidelines are indexed by the EQUATOR Network, which keeps a searchable library of them. Many journals require a completed checklist at submission, with the page number where each item appears.

Start with the study design

The guideline you need depends on what kind of study you ran, and only secondarily on the fact that AI was involved. So the first question is the one a methodologist would ask about any paper.

Your study Guideline First published
Protocol for a randomized trial of an AI intervention SPIRIT-AI 2020
Report of a randomized trial of an AI intervention CONSORT-AI 2020
Diagnostic accuracy of a test against a reference standard STARD 2015, and STARD-AI 2015, 2025
Developing or validating a prediction model TRIPOD+AI 2024
Early live clinical evaluation of an AI decision support tool DECIDE-AI 2022
Any AI study in medical imaging CLAIM 2020, updated 2024

Most AI papers written by clinical researchers are diagnostic accuracy studies or prediction model studies, so STARD and TRIPOD+AI are the two you are most likely to use. The trial guidelines apply once you get as far as testing the tool on patients in a randomized design, which few projects do (see 5.3 Designing Prospective Clinical Validation Studies).

CONSORT-AI and SPIRIT-AI: randomized trials

These two were developed together by the same international group and published in 2020. Both are extensions: you complete the parent checklist (CONSORT 2010 for trial reports, SPIRIT 2013 for trial protocols) and the AI items on top.

The AI items are about the things that make an AI intervention different from a drug. They ask you to:

  • State which version of the algorithm was used, and whether it changed during the trial.
  • Describe the input data the algorithm needs, how it was acquired, and what happened to inputs that were poor quality or unavailable.
  • Describe how the AI output was presented to the people using it, and what they were expected to do with it. An AI intervention is the algorithm plus the humans around it.
  • Describe how the intervention was fitted into the trial setting, including any on-site or off-site requirements.
  • Say how errors of the algorithm were identified and analysed.
  • Say whether and how the algorithm or its code can be accessed.

The last few items are the ones authors most often skip. A trial that reports "clinicians used the AI system" without saying whether they could override it, or what they saw on screen, hasn't described its intervention.

SPIRIT-AI asks for the same things in the future tense, in the protocol. If you write the protocol to SPIRIT-AI, the CONSORT-AI checklist at the end is mostly a matter of copying your plan and reporting what happened.

STARD and STARD-AI: diagnostic accuracy

STARD (Standards for Reporting of Diagnostic Accuracy Studies) covers any study that compares an index test against a reference standard and reports sensitivity, specificity or similar. It first appeared in 2003 and the current version is STARD 2015. A model that reads an image and says "disease" or "no disease" is an index test, so this is the natural home for a lot of imaging AI papers.

STARD's core demands will be familiar: how participants were selected (consecutive, random or convenience sample), what the reference standard was and why, whether the people applying the reference standard knew the index test result, a flow diagram of participants, and a 2x2 table from which the reader can recompute your numbers.

The AI-specific version, STARD-AI, was announced in 2020 and published in 2025. It adds items on the datasets used to train and test the model, on how the test set was kept apart, and on how the algorithm's output was turned into a diagnosis. If your journal doesn't yet ask for it, completing STARD 2015 together with CLAIM (below) covers much the same ground.

TRIPOD+AI: prediction models

TRIPOD (Transparent Reporting of a multivariable prediction model for Individual Prognosis Or Diagnosis) was published in 2015, when "prediction model" mostly meant logistic regression. TRIPOD+AI, published in 2024, replaces it and covers prediction models built by any method, regression or machine learning.

It applies when you develop a model that estimates a probability or risk for an individual, when you validate one, or both. Risk scores from electronic health record data are the obvious case. A lot of imaging AI fits too, whenever the output is a probability of a diagnosis or outcome.

Some of what TRIPOD+AI asks for goes beyond the older checklist:

  • The source of the data and how representative it is of the intended population.
  • Sample size, with a justification.
  • How missing data was handled.
  • Calibration as well as discrimination (see 4.4 Calibration).
  • Performance in key subgroups, under a heading of fairness.
  • Whether code, data and the model itself are available.
  • Involvement of patients and the public.

It also comes with a separate checklist for abstracts, which is worth a look, since the abstract is all most people read.

Diagnostic accuracy study or prediction model study? Authors do get stuck on this, and many papers are honestly both. A rough rule: if you took a finished model and tested its yes/no output against a reference standard, STARD fits. If the paper's subject is building the model and reporting how well its probabilities perform, TRIPOD+AI fits. When in doubt, check what the target journal asks for.

The supporting cast

CLAIM, the Checklist for Artificial Intelligence in Medical Imaging, was published in 2020 by the editors of the journal Radiology: Artificial Intelligence and updated in 2024. It is modelled on STARD and is the most useful of the lot for imaging work, because it asks imaging-specific questions: how images were acquired and preprocessed, how the annotations were made and by whom, how the data was partitioned, and the details of the model and its training. Radiology journals commonly require it.

DECIDE-AI, published in 2022, fills the gap between a retrospective accuracy study and a full trial. It covers the first small-scale use of a decision support tool in live clinical care, where the questions are about safety, usability and how clinicians actually respond to the output.

TRIPOD-LLM, published in 2025, extends TRIPOD to studies that use large language models, where the "model" may be a commercial product that changes without notice and the "input" includes a prompt (see 1.4 Foundation Models and Large Language Models in Clinical Research).

Then the risk of bias tools. QUADAS-2 is used to assess diagnostic accuracy studies and PROBAST to assess prediction model studies, and an updated PROBAST+AI appeared in 2025. You don't submit these with a paper. They are worth reading anyway, because they list the questions a careful reviewer will ask about your design, and those questions can't be fixed in the writing.

Use the checklist before you have data

This is the most useful thing we can tell you about reporting guidelines: read the one that applies before the study starts.

Nearly every item on these checklists corresponds to a decision or a record that has to exist at the time. A few examples:

  • STARD wants to know how participants were sampled. If nobody recorded how the cases were pulled from the archive, you can't answer.
  • TRIPOD+AI wants a sample size justification. Writing one after the results are in is an exercise in creative writing.
  • CONSORT-AI wants the algorithm version. If the engineers updated the model twice during the study and didn't tag the versions, the information is gone.
  • CLAIM wants the annotators' qualifications and the agreement between them. That needs a double-read sample planned into the annotation work (see 2.3 Data Annotation and Labeling for Clinical AI).

Treated as a design checklist, a guideline costs an hour at the start and saves you from discovering at submission that an item can't be completed. It also works pretty well as an agenda for the first planning meeting with your engineering team, since it forces the conversation about test sets, versions and records that would otherwise happen too late (see 3.6 Working with an Engineering Team: The Clinician's Role).

How well are they followed?

Not very, so far. Reviews of the published literature keep finding the same omissions. In 2019 Xiaoxuan Liu and colleagues reviewed studies comparing deep learning with health care professionals for diagnosis from medical images. Of 82 studies, 25 had validated the model on data from outside the development set, and 14 had compared model and clinicians on the same sample. In 2020 Myura Nagendran and colleagues looked at studies claiming that deep learning matched or beat clinicians, and found that of 81 non-randomized studies, 9 were prospective and 6 were tested in a real clinical setting. Many didn't report enough to judge their risk of bias at all.

The upside for you is that a paper that does complete the right checklist stands out to editors and reviewers, and is much easier to defend.

A workable routine

  1. At the design stage, identify the study type and pull the matching guideline and its explanation document. The explanation documents give examples of good reporting for every item and are far more useful than the bare checklist.
  2. For imaging studies, add CLAIM.
  3. Turn the items into a list of things to record during the study, with a name beside each.
  4. Check the target journal's instructions. Some name a specific guideline, and some want the checklist uploaded.
  5. At writing time, fill in the checklist with page numbers, and where an item doesn't apply or wasn't done, say so in the paper.

That last point is worth taking seriously. The guideline doesn't require you to have done everything. It requires you to be clear about what you did. "No external validation was performed" is a complete report of that item, and an honest limitation is easier on a reviewer than a silence they have to guess about.

Key takeaways

  • Reporting guidelines list what a paper has to disclose. They don't measure study quality, though following one makes the quality visible.
  • Choose by study design: SPIRIT-AI for trial protocols, CONSORT-AI for randomized trials, STARD and STARD-AI for diagnostic accuracy, TRIPOD+AI for prediction models, DECIDE-AI for early live evaluation.
  • For medical imaging, CLAIM asks the imaging-specific questions and is widely required by radiology journals.
  • The AI extensions add items on algorithm version, input data, how the output reached the user, error analysis and access to code.
  • QUADAS-2 and PROBAST are risk of bias tools. Reading them shows what reviewers will ask about the design.
  • Read the guideline at the design stage and turn it into a list of records to keep. Most items can't be reconstructed afterwards.

This article is part of the AI in Clinical Research Knowledge Base.