Peer Review of AI Manuscripts: What Reviewers Look For
Understanding the evaluation criteria that journals and reviewers apply to AI papers. A practical guide for both authors preparing submissions and clinicians asked to review AI research.
Sooner or later a journal will send you an AI manuscript to review, because you know the disease and the editor needs someone who does. The usual first reaction is that you aren't qualified, since you couldn't say whether a ResNet-50 was a sensible choice.
You are more qualified than you think. Most of what decides whether an AI paper is sound is clinical epidemiology: who the patients were, what the reference standard was, whether the test was fair. The architecture is rarely where a paper goes wrong, and the journal will usually have a technical reviewer for that side anyway.
This article is written for both chairs. The first part describes how to review an AI manuscript, and the second turns the same list around for authors.
What editors want from you
An editor is trying to answer three questions. Is the clinical question worth asking? Do the methods support the conclusions? Is the paper reported well enough for readers to judge for themselves?
A clinical reviewer is the main source of the first answer and a major source of the second. Say in your comments to the editor which parts you have assessed and which you haven't ("I have not evaluated the network architecture or training details"). Editors appreciate that, and it tells them whether a technical reviewer is still needed.
Several journals have published their own guidance. A well-known example is a 2020 editorial from the editorial board of Radiology, with David Bluemke as first author, which sets out a short list of things authors, reviewers and readers should look for in AI research. Its items overlap heavily with what follows: a clearly defined reference standard, properly separated training and test data, external testing, comparison with experts, and results that can be reproduced.
A reading order that works
Reading an AI paper front to back tends to leave you impressed by the results before you know how they were produced. We'd suggest a different order.
- The abstract and the final paragraph, to see what is being claimed.
- The data and reference standard sections of the methods.
- The description of the data split and the evaluation.
- The limitations paragraph, to see what the authors already admit.
- The results, tables and figures.
- The model and training details.
- The supplement, at least as far as the flow diagram and the subgroup tables.
By step 4 you will usually know whether the paper's claims can stand, and the results can then be read with the right amount of scepticism.
The clinical question
Start where your expertise is strongest.
Is this a problem that needs solving? A model that detects something clinicians already detect reliably and quickly may be a fine piece of engineering with no use. Ask what decision the output would change.
Is the intended use stated? Who would use the model, on which patients, at what point in care? A paper that never says can't be evaluated, because there's nothing to compare the test population against.
Is the task defined the way clinicians define it? You are the person who will spot that "pneumonia" in this dataset means "the word pneumonia appeared in the report," or that the two classes being separated are never a real diagnostic dilemma.
Does the paper compare against what is done now? That might be unaided clinicians, an existing risk score, or a simpler model.
The data
You know what patients with this disease look like, so check that the dataset resembles them.
- How were cases selected, and from where? Consecutive patients, or a convenience sample? Were positives and negatives found the same way?
- How many patients are there, as distinct from images?
- What was excluded and why? Would the excluded cases occur in practice?
- Is there a table of demographics and disease severity for each partition, and does the case mix look like a real clinic?
- What was the prevalence in the test set, and how does it compare with the setting the model is meant for?
- Which scanners and sites contributed?
2.1 Why Data Quality Matters More Than Model Complexity explains why these questions carry so much weight.
The reference standard
This is the section where a clinical reviewer is hardest to replace. An engineer will generally accept "ground truth was established by two radiologists" as it stands. You know whether two radiologists can establish that particular truth.
Ask whether the reference standard is appropriate for the disease, who applied it and with what information, whether they were blind to the model's output, how disagreements were settled, and what the agreement was. Ask whether positives and negatives were verified in the same way. If the labels came from reports or codes, ask how accurate that process is (see 5.7 Reference Standards and Ground Truth in Medical AI).
The split and the test
You don't need to understand how the model was trained to check that it was tested fairly. Four questions do most of the work.
Was the data split by patient? If the manuscript doesn't say, ask. This is probably the most useful question a reviewer can put to the authors of an AI paper.
Was the test set kept apart until the end? Look for a separate tuning set and for a statement about how the final model and the threshold were chosen.
Is any of the test data external? If all of it comes from the development sites, the conclusions need to be limited accordingly.
Was the comparison with clinicians fair? Check the readers' experience, the information they had and the reading conditions.
9.3 Common Methodological Pitfalls in Medical AI Papers goes through each of these and the others in more detail.
The results
Check that performance is reported with confidence intervals, with more than one metric, and at an operating point somebody would actually use. Check for subgroup results. Look for an error analysis: do the authors show and discuss the cases the model got wrong? A paper with examples of failures is usually a paper whose authors looked at their data.
Then do a little arithmetic. Do the numbers in the abstract match the tables? Can you rebuild the sensitivity from the 2x2 counts? Do the patient numbers in the flow diagram add up? Small inconsistencies are common, and they are worth pointing out, since they sometimes lead to larger ones.
Be a bit wary of results that are extremely good. An AUC of 0.99 on a hard clinical problem is possible, but leakage or a shortcut is a likelier explanation, and it is reasonable to ask the authors what they did to rule those out.
The conclusions
Compare what was shown with what is claimed. A retrospective accuracy study supports "the model classified these images with this accuracy." It doesn't support "the model improves diagnosis" or "can reduce workload," which need a study of clinicians using it (see 5.1 Technical Validation vs. Clinical Validation). Asking for the conclusions to be toned down to match the design is one of the most common and most useful review comments.
Check that the limitations section names the real limitations. "Further prospective studies are needed" appears in nearly every paper and tells the reader very little. A single site, a small number of positives or an imperfect reference standard should be named specifically.
Reporting and availability
Check whether the authors completed the reporting guideline that fits the design, and whether the checklist was honestly filled in (see 9.1 Reporting Standards). Look at the data and code availability statements. You can't insist on open data, but you can ask why code isn't available and note it for the editor (see 9.4 Sharing Code, Data, and Models).
Writing the review
A helpful review is specific. "The methodology is weak" gives the authors nothing to do. "Please state whether the split was performed at the patient level, and report the number of patients in each partition" can be answered in a sentence and settles a real question.
Some habits we'd recommend:
- Separate major concerns, which affect whether the conclusions hold, from minor ones.
- Ask for information before assuming the worst. An unreported detail may have been done correctly.
- Request analyses that can be done with the existing data: confidence intervals, subgroup results, a simple baseline, performance at a clinically chosen threshold. Asking for a new external dataset is fair when the claims need one. Otherwise, ask for the claims to be narrowed.
- Don't penalise honesty. A paper that reports modest performance, with proper intervals and a frank limitations section, is worth more than a spectacular one that can't be checked.
- Stay within your expertise, and say where its edges are.
For authors: reviewing your own paper first
Everything above is a list of what your reviewers will do, so the cheapest way to an easier review is to do it yourself before submitting. A few things make a particular difference.
Answer the standard questions in the text. Patient-level split, threshold selection, number of patients, reader blinding and agreement. Reviewers ask these almost every time, and each one you leave out costs a revision round.
Put the limitations in yourself. Reviewers are much kinder to a weakness the authors have named and discussed than to one they had to find.
Match your claims to your design. Overstated conclusions are the most frequent reason a sound study gets a hard review.
Include the failures. A figure of misclassified cases with a paragraph on what they have in common shows that you understand your model.
Expect two kinds of reviewer. The clinical reviewer wants to know who the patients were, and the technical reviewer wants to know how the model was trained. Give each a clear section, and move the engineering detail that a clinician won't read into the supplement.
Choose the journal with the audience in mind. A clinical journal will care most about the population and the clinical consequence, and an imaging AI journal will expect more technical depth and probably a CLAIM checklist.
And when the reviews come back, answer every point, quote the changed text, and where you disagree, say why with evidence. Reviewers are, like you, doing this unpaid in the evening.
Key takeaways
- A clinical reviewer is qualified to judge most of what makes an AI paper sound: the question, the patients, the reference standard and the fairness of the test.
- Read the methods on data, reference standard and splitting before the results.
- Ask whether the split was by patient, whether the test set was held back, whether any test data was external and whether the human comparison was fair.
- Check for confidence intervals, subgroup results, an error analysis and numbers that add up.
- Compare conclusions with design, and ask for claims to be narrowed where they go beyond it.
- Write specific, answerable comments, and say which parts of the paper you did not assess.
- Authors can apply the same list to their own manuscript before submission, and should state limitations and match claims to the study that was done.
What to read next
- 9.3 Common Methodological Pitfalls in Medical AI Papers: the errors reviewers are looking for
- 9.1 Reporting Standards: CONSORT-AI, SPIRIT-AI, TRIPOD+AI, and STARD: the checklists journals ask for
- 9.2 Writing the Methods Section for an AI Study: giving reviewers what they need
- 4.5 Statistical Significance, Confidence Intervals, and Sample Size for AI Studies: the statistics reviewers expect
- D. Checklist: Is Your AI Study Ready for Publication?: a pre-submission list
This article is part of the AI in Clinical Research Knowledge Base.