Regulatory Standards Quick Reference
A consolidated table of applicable standards (ISO 13485, IEC 62304, ISO 14971, IEC 62366, GMLP, etc.) with scope, applicability, and harmonization status.
Regulatory conversations are conducted largely in numbers: "that's a 62304 question," "it's in your 14971 file." This page lists the ones you will hear, says what each covers and who it applies to, and points to the article that explains it.
This is a lookup table and not regulatory advice. Standards are revised, guidance is updated, and the edition a regulator accepts changes over time, so confirm the current version before you rely on any of it.
Three kinds of document
It helps to know which kind of thing you are looking at, because they bind you in different ways.
A regulation is law. In the US these are parts of Title 21 of the Code of Federal Regulations (21 CFR). In Europe they are EU regulations such as the MDR. You have to comply.
A consensus standard is written by a standards body such as ISO or IEC. Standards are voluntary on paper. In practice regulators recognize particular standards as an accepted way to meet a requirement, so following them is the path of least resistance and departing from them means explaining yourself. You have to buy most of them.
A guidance document is a regulator's description of how it currently interprets the law. It is not binding, and reviewers follow it closely.
The table
| Document | Kind | What it covers | Who needs it | Read more |
|---|---|---|---|---|
| ISO 13485:2016 | Standard | Quality management systems for medical device manufacturers: design control, document control, suppliers, complaints | Anyone who will market a device, in any major jurisdiction | 6.10 |
| 21 CFR Part 820 | US regulation | The FDA's quality system requirements. Formerly the Quality System Regulation (QSR), now the Quality Management System Regulation (QMSR), which incorporates ISO 13485 | Manufacturers selling in the US | 6.10 |
| MDSAP | Audit program | One audit of an ISO 13485 quality system, accepted by the US, Canada, Japan, Australia and Brazil | Required for Health Canada Class II to IV licences. Optional and efficient elsewhere | 6.11 |
| ISO 14971:2019 | Standard | Risk management for medical devices: identifying hazards, estimating and controlling risk, monitoring after release | Every device manufacturer | 6.10 |
| ISO/TR 24971 | Technical report | Guidance on applying ISO 14971 | Whoever writes your risk management file | |
| AAMI TIR34971 | Technical report | Applying ISO 14971 to machine learning: hazards from data, bias, drift and so on | Teams building ML-enabled devices | |
| IEC 62304 | Standard | Software lifecycle processes for medical device software, with safety classes A, B and C | Every team writing device software | 6.9 |
| IEC 82304-1 | Standard | Product safety requirements for health software that runs on general-purpose hardware, which is to say standalone software | SaMD manufacturers, mainly for Europe | |
| IEC 62366-1 | Standard | Usability engineering: showing that users can operate the device safely | Any device with a user interface | 8.4 |
| IEC 81001-5-1 | Standard | Security activities across the health software lifecycle | Software manufacturers. Sits alongside IEC 62304 | |
| 21 CFR Part 11 | US regulation | Electronic records and electronic signatures | Anyone keeping regulated records electronically, which is everyone | |
| 21 CFR Part 807, Subpart E | US regulation | Premarket notification, the 510(k) | Class II devices with a predicate | 6.3 |
| 21 CFR Part 860, Subpart D | US regulation | De Novo classification | Novel low-to-moderate risk devices with no predicate | 6.4 |
| 21 CFR Part 814 | US regulation | Premarket approval (PMA) | Class III devices | 6.5 |
| 21 CFR Part 812 | US regulation | Investigational device exemptions, for clinical studies of devices not yet cleared | Sponsors of prospective device studies in the US | 5.3 |
| 21 CFR Part 803 | US regulation | Medical device reporting of adverse events | Manufacturers with a device on the US market | 6.12 |
| 21 CFR Part 806 | US regulation | Reports of corrections and removals | Manufacturers with a device on the US market | 6.12 |
| ISO 14155 | Standard | Good clinical practice for clinical investigations of medical devices | Sponsors and investigators running device trials | 5.3 |
| GMLP guiding principles (2021) | Guidance | Ten principles for machine learning in device development, from the FDA, Health Canada and the MHRA | Every team building an ML-enabled device | 6.7 |
| FDA PCCP guidance | US guidance | What a predetermined change control plan for an AI-enabled device must contain | Teams that expect to update a model after clearance | 6.8 |
| FDA clinical decision support guidance | US guidance | Which decision support software is and is not a device | Anyone hoping their software is exempt | 6.1 |
| FDA guidance on premarket submissions for device software functions | US guidance | The software documentation a submission has to include | Anyone preparing a US submission | 6.3 |
| FDA premarket cybersecurity guidance | US guidance | Security documentation for submissions, including a software bill of materials | Anyone preparing a US submission for connected software | |
| IMDRF SaMD documents | International guidance | Definitions, risk categorization and clinical evaluation of Software as a Medical Device | Useful background everywhere. Several regulators build on them | 6.1 |
| Health Canada MLMD guidance (2025) | Canadian guidance | Pre-market expectations for machine learning-enabled devices, including change control plans and SGBA Plus analysis | Manufacturers applying for a Canadian licence | 6.11 |
| Medical Devices Regulations (SOR/98-282) | Canadian regulation | Device classes I to IV and licensing in Canada | Manufacturers selling in Canada | 6.11 |
| EU MDR (Regulation 2017/745) | EU regulation | Medical devices in the EU: classification, Notified Body assessment, CE marking, post-market surveillance | Manufacturers selling in the EU | 6.11 |
| EU AI Act (Regulation 2024/1689) | EU regulation | Requirements for high-risk AI systems, a category that takes in most AI medical devices: data governance, transparency, human oversight | Manufacturers selling AI devices in the EU. Medical device provisions apply from 2 August 2028, after a 2026 amendment (Regulation 2026/1744) moved the date back from August 2027 | 6.11 |
| HIPAA Privacy Rule (45 CFR Parts 160 and 164) | US regulation | Use and disclosure of protected health information, and de-identification | Anyone using US patient data | 2.7 |
| Common Rule (45 CFR Part 46) | US regulation | Protection of human research subjects and IRB review | Researchers at US institutions | 2.7 |
| GDPR (Regulation 2016/679) | EU regulation | Processing of personal data, including health data | Anyone using data about people in the EU | 2.7 |
| TCPS 2 | Canadian policy | Ethical conduct for research involving humans, applied by research ethics boards | Researchers at Canadian institutions | 2.7 |
| DICOM | Standard | Format and exchange of medical images. Part 15 covers de-identification | Anyone handling medical images | 8.3 |
| HL7 FHIR | Standard | Exchange of clinical data between systems | Teams integrating with an EHR | 8.3 |
How they fit together
The quality system (ISO 13485, 21 CFR Part 820) is the container. It says you must have documented procedures for designing, building, changing and monitoring your device. The other standards fill in particular procedures: ISO 14971 for risk, IEC 62304 for software, IEC 62366-1 for usability, IEC 81001-5-1 for security. They refer to one another constantly. IEC 62304's safety class comes out of your ISO 14971 risk analysis, for example.
The pathway regulations (510(k), De Novo, PMA) describe how you ask for permission to sell. The submission you send is mostly evidence that you followed the standards above, plus your performance data.
The AI-specific documents (GMLP, the PCCP guidance, the Health Canada MLMD guidance, the EU AI Act) sit on top. None of them replaces the general device rules. They add expectations about training data, test data independence, subgroup performance, transparency and how the model changes.
Harmonization and recognition status
Whether a given edition of a standard is officially accepted depends on the jurisdiction, and the lists change.
In the US, the FDA keeps a searchable database of recognized consensus standards. Look up the standard there to see which edition is recognized and to what extent. Since February 2026 the QMSR has incorporated ISO 13485:2016 into 21 CFR Part 820 by reference.
In the EU, a standard gives a presumption of conformity with the MDR only once its reference has been published in the Official Journal as a harmonised standard under that regulation. The list for the MDR has been filling in gradually. Check the European Commission's current list instead of assuming a standard is on it.
In Canada, Health Canada publishes its own list of recognized standards for medical devices.
As of November 2026, this is where the main standards stood on the first two lists:
| Standard | FDA recognized | Harmonised under the EU MDR |
|---|---|---|
| ISO 13485:2016 | Not in the recognition database; incorporated by reference in the QMSR | Yes |
| ISO 14971:2019 | Yes | Yes |
| IEC 62304 (2006 with Amendment 1) | Yes | No |
| IEC 62366-1 (2015 with Amendment 1) | Yes | No |
| IEC 81001-5-1:2021 | Yes | No |
| IEC 82304-1:2016 | Yes | No |
| ISO 14155 | Not checked | Yes, both the 2020 and 2026 editions for now |
A standard that isn't harmonised under the MDR is still what a Notified Body will expect you to follow. Without the harmonisation it counts as the state of the art, and you don't get the formal presumption of conformity.
Editions
The year after the colon is the edition. The ones in common use as of this writing:
- ISO 13485:2016
- ISO 14971:2019, with its guidance ISO/TR 24971:2020
- IEC 62304:2006 with Amendment 1 from 2015. You will see this written as IEC 62304:2006+AMD1:2015. A second edition is being drafted and had not been published as of November 2026.
- IEC 62366-1:2015, with an amendment from 2020
- IEC 82304-1:2016
- IEC 81001-5-1:2021
- ISO 14155:2026, which replaced the 2020 edition in March 2026
If your consultant quotes a different year, ask which one your regulator currently recognizes. It is a routine question.
What a research group needs before there is a product
Not much of this, yet. A research lab is not a manufacturer and does not need an ISO 13485 certificate to publish a paper.
What is worth doing early, because it is nearly impossible to reconstruct later, is keeping the records the standards will eventually ask for: where the data came from and under which approval, the annotation protocol and its versions, which data trained which model, and what the test results were. 6.10 explains why, and 6.7 describes the habits regulators hope to see.
This article is part of the AI in Clinical Research Knowledge Base.